US add:92 CORPORATE PARK STE C204, IRVINE, 92606 CA, US
China Add : Zone A of 1st and 2nd Floor, and 3rd Floor, Building A, No. 7, Tongsheng Industrial Park Road, Shanghenglang Community,Dalang Street, Longhua District, 518109 Shenzhen,PLA
E-mail:marketing@medxing.com
The SpO2 sensor is equipped with a temperature sensor. After being matched with dedicated adapter cable and monitor, it has a partial over-temperature monitoring function, which reduces the risk of burns and reduces the burden of regular inspections by medical personnel.
1) The patient's measurement site has weak perfusion and cannot take away the sensor temperature through normal blood circulation;
2) The measurement site is too thick; (for example, the foot of newborns whose weight are more than 3.5KG are too thick and should not be wrapped for measurement)
3) Failure to regularly check the sensor and change the position.
1.Please read the instructions carefully before use, and use the product according to the instructions;
2.When the skin temperature of the patient's monitoring site exceeds 41℃, the sensor will stop working immediately. At the same time, the indicator light of the SpO2 sensor adapter cable emits a red light, and the monitor emits an alarm sound, which prompts medical personnel to take timely measures to avoid burns;
3.When the skin temperature drops below 41℃, the sensor will restart to monitor SpO2.
1. Over-temperature monitoring: there is a temperature sensor at the probe end. After matching with a dedicated adapter cable and monitor, it has a partial over-temperature monitoring function, reducing the risk of burns and reducing the burden of regular inspections by medical personnel;
2. More comfortable: the smaller space of the probe wrapping part and good air permeability;
3. Efficient and convenient: v-shaped probe design, quick positioning of the monitoring position; connector handle design, easier connection;
4. Safety guarantee: good biocompatibility, no latex;
5. High accuracy: evaluation of SpO2 accuracy by comparing arterial blood gas analyzers;
6. Good compatibility: it can be adapted to mainstream brand monitors, such as Philips, GE, Mindray, etc;
7. Clean, safe and hygienic: production and packaging in the clean workshop to avoid cross-infection.
1. Operating Room (OR)
2. ICU
3. Neonatology
4. Internal Cardiovascular Dept.
5. Cardiothoracic Surgery Dept.

Adapters | Disposable SpO2 Sensors | ||||
|---|---|---|---|---|---|
Product Picture | Order Code | Descriptions | Product | Order Code | Descriptions |
![]() | S0026OP-A | 9pin to | ![]() | 604480102(EU) | Adult, Pediatric,Infant,Neonatal,Comfort Foam |
![]() | 604470102(EU) | Adult, Pediatric,Infant,Neonatal, | |||
![]() | S0442OP-A | 9pin to | ![]() | 604370102(EU) | Infant, Elastic |
![]() | 604260101(EU) | Pediatric, | |||
![]() | 604160101(EU) | Adult, | |||
Address:Zone A of 1st and 2nd Floor, and 3rd Floor, Building A, No. 7, Tongsheng Industrial Park Road, Shanghenglang Community,Dalang Street, Longhua District, 518109 Shenzhen,PLA
Tel:(86) 400-058-0755
E-mail:marketing@medxing.com
whatsapp: +872 57428634