Blood pressure is an important indicator of the human body's vital signs. The level of blood pressure can help determine whether the human body's heart function, blood flow, blood volume, and vasomotor function are normally coordinated. If there is an abnormal increase or decrease in blood pressure, it indicates that there may be some abnormalities in these factors.
Blood pressure measurement is an important means to monitor the vital signs of patients. Blood pressure measurement can be divided into two types: IBP measurement and NIBP measurement.
IBP refers to the insertion of a corresponding catheter in the body, accompanied by puncture of blood vessels. This blood pressure measurement method is more accurate than NIBP monitoring, but there is a certain risk. IBP measurement is not only used on laboratory animals. It is not commonly used anymore.
NIBP measurement is an indirect method of measuring human blood pressure. It can be measured on the body surface with a sphygmomanometer. This method is easy to monitor. Currently, NIBP measurement is the most widely used in the market. Blood pressure measurement can effectively reflect a person’s vital signs. Therefore, blood pressure measurement must be accurate. In reality, many people adopt wrong measurement methods, which often lead to errors between the measured data and the real blood pressure, resulting in inaccurate data. The following is correct. The measurement method is for your reference.
The correct method of NIBP measurement:
1. Smoking, drinking, coffee, eating and exercising are prohibited 30 minutes before the measurement.
2. Make sure that the measurement room is quiet, let the subject rest quietly for 3-5 minutes before starting the measurement, and make sure to avoid talking during the measurement.
3. The subject should have a chair with his feet flat, and measure the blood pressure of the upper arm. The upper arm should be placed at the level of the heart.
4. Choose a blood pressure cuff that matches the subject’s arm circumference. The subject’s right upper limb is bare, straightened and abducted for about 45°. The lower edge of the upper arm is 2 to 3 cm above the elbow crest; the blood pressure cuff should not be too tight or too loose, generally it is better to be able to extend a finger.
5. When measuring blood pressure, the measurement should be repeated 1 to 2 minutes apart, and the average value of the 2 readings should be taken and recorded. If the difference between the two readings of systolic blood pressure or diastolic blood pressure is more than 5mmHg, it should be measured again and the average value of the three readings shall be recorded.
6. After the measurement is completed, turn off the sphygmomanometer, remove the blood pressure cuff, and fully deflate. After the air in the cuff is completely discharged, the sphygmomanometer and cuff are put in place.
When measuring NIBP, NIBP cuffs are often used. There are many styles of NIBP cuffs on the market, and we often face the situation of not knowing how to choose. Medlinket NIBP cuffs have designed a variety of different types of NIBP cuffs for different application scenarios and people, suitable for different departments.
Reusabke NIBP cuffs include comfortable NIBP cuffs (suitable for ICU) and nylon blood pressure cuffs (suitable for use in emergency departments).
Product advantages:
1. TPU and nylon material, soft and comfortable;
2. Contains TPU airbags to ensure good air tightness and long life;
3. The airbag can be taken out, easy to clean and disinfect, and can be reused.
Disposable NIBP cuffs include non-woven NIBP cuffs (for operating rooms) and TPU NIBP cuffs (for neonatal departments).
Product advantages:
1. The disposable NIBP cuff can be used for single patient, which can effectively prevent cross-infection;
2. Non-woven fabric and TPU material, soft and comfortable;
3. The neonatal NIBP cuff with transparent design is convenient for observing the skin condition of patients.
Related News
- Medlinket's physical sign monitoring equipment is a "good...
- Medlinket won the "Top 10 Best Reputation Equipment a...
- Medlinket's Infant Incubator, Warmer Temperature Probe...
- Long-term SpO2 monitoring will cause skin burn risk?
- New product recommendations:Medlinket disposable IBP ...
- Medlinket's NIBP cuff adapts to the needs of different d...
- Medlinket's Compatible Welch Allyn Smart Temp Prob...
- How to choose a reusable SpO2 sensor?
- Medlinket disposable EEG sensors to provide accurate mo...
- Medlinket's pelvic floor muscle rehabilitation probe helps...
- Pelvic floor rehabilitation probe manufacturer, manufactu...
- Why is the body cavity temperature probe generally selecte...
- Medlinket's One-Piece ECG Cable with LeadWires is ...
- Medlinket's blood oxygen probe is highly accurate, escortin...
- Medlinket professionally developed a high-precision oximet...
- Medlinket's products obtaining the UK MHRA registrat...
- Medlinket's disposable NIBP cuff protector can effective...
- Medlinket disposable defibrillation electrode are registere...
- Medlinket's Y-type multi-site SpO2 probe, a small expe...
- Medlinket’s disposable NIBP cuff, specially designed fo...
- Medlinket's disposable non-invasive EEG sensor helps to ...
- Pelvic floor rehabilitation probe manufacturer, recognize ...
- Pelvic floor rehabilitation can not be ignored ,Look for M...
- Medlinket Digital Infrared Thermometer, a good helper f...
- End expiratory carbon dioxide sensor and sampling tube acc...
- Medlinket's temp-pulse oximeter realizes five major heal...
- Low SpO2, have you found the reason behind it?
- Manufacturers of disposable EEG sensors prefer Medlinke...
- Medlinket’s home portable Temp-Pluse oximeter, scient...
- Why does anesthesiology department use disposable spo2 sen...
- Medlinket's disposable temperature probe meets the needs ...
- Medlinket Temp-plus oximeter, the patron saint of health...
- How to choose suitable disposable SpO2 sensor in differe...
- Medlinket anesthesia depth EEG sensor has obtained MHR...
- Medlinket's disposable NIBP cuff can effectively reduce ...
- The manufacturer of pelvic floor rehabilitation probe is t...
- NIBP measurement method and choice of NIBPcuff
- Medlinket's internal electrode for pelvic floor muscle the...
- Expert consensus on emergency end expiratory carbon dioxid...
- What types of oximeters are there? How to buy it?
- For ETCO2 monitoring, intubated patients are most sui...
- Medlinket's anti-jitter high-precision Temp-Pluse oxime...
- A high-precision oximeter that meets clinical testing, a
- Disposable non-invasive EEG sensor, supplied by the man...
- What are the characteristics of Medlinket’s new silicone...
- In 2021 CMEF/ICMD autumn exhibition, Medlinket invi...
- How to select spo2 sensor in various departments of the h...
- How is Medlinket's disposable non-invasive EEG sensor ...
- Internationally acclaimed oximeter——Medlinket’s tempe...
- What are the types of disposable non-invasive EEG sensor...
- To monitor the patient's respiratory status, it is necessa...
- The clinical significance of temperature management duri...
- The difference between disposable Skin-surface temperatu...
- Why should we use disposable noninvasive EEG sensors to...
- "Guardian God" for Premature Infants-ncubator Temperat...
- What is the difference between mainstream CO2 sensor a...
- The importance of disposable temperature probes in clinic...
- Application scenarios and usage methods of Disposable Sp...
- For the bidding of disposable EEG sensor manufacturers,...
- Will the SpO2 sensor cause neonatal skin burns in SpO2...
- How to choose the appropriate disposable anesthesia depth ...
- SpO2 of Novel Coronavirus Pneumonia testing standards
- Application scenarios and applicable people of different S...
- Medlinket's ETCO2 mainstream and sidestream sensors ...
- Why choose a disposable non-invasive EEG sensor adapted ...
- Medlinket's disposable non-invasive EEG sensor has been ...
- Medlinket depth-of-anesthesia sensor helps anesthesiologist...
- Medlinket Adult Finger Clip Oximetry Probe, a great h...
- FIME2018
- 2018 Med-link Medical Exhibitions Preview
- [Exhibition notice] Med-linket’s exhibition overview in ...
- 2017 American Society Of Anesthesiologists Annual Con...
- [Exhibition Invitation]Med-linket Invited You To Partic...
- Med-link Participated In The 2017 Annual Meeting Of A...